FEATURES Photoeletric sensor samples the air every 5 seconds and triggers an alarm if prescribed levels of smoke appears. Red LED "power on" indicator. 12-unit multiple station interconnect, with originating alarm indicator. Test button checks horn and alarm circuitry. AC quick-connect power harness. Loud piercing, pulsating horn. Insect-resistant screen minimizes nuisance alarms. Special twist-off trim ring for fast installation with removable tamperproof tab option. UL listed. 5 year (limited) warranty. PRINCIPLES OF OPERATION Detects smoke by Photoeletric process. RATINGS Approvals: Meets UL 217 and FCG standard for lightning protection. Auditory: Loudness: 85 dB minimum @ 10 ft. Duration: Continuous while smoke is present. Electrical: Voltage: 120 VAC Amperage: .025 Amps maximum current (alarm and standby). Emi Regulations: Special shielding for RF immunity. Solid State Circuitry: 100% solid state. Temperature: Installation: 135° F, 50ft. space rating (cannot be used where ambient temperature exceeds 92° F). Operating: 40° F - 100° F Miscellaneous: Humidity: 10 - 90% relative humidity SIZE Diameter: 5 1/2 " Height: 2 1/2 " APPLICATIONS Interconnectability: Please Note: These detectors are designed to work only with other model 5919's. They may not trigger other devices including alarm bells and other brands of smoke detectors. Fits: Fits up to 4" octagonal electrical boxes. |
| In an effort to protect our customers, all order's placed online will be subject to credit verification. Your order must include the correct billing address for processing. In some situations where the purchase appears to be suspicious we will contact the issuing bank for verification of cardholder. |