iGuard LM Series iGuard Reader w/ Embedded Web Server, Fingerprint & Smart Card (1,000 Users) Master Only

|
 |
 |
iGuard Facility Access Fingerprint/Smart Card 1000 Users

|
 |
 |
iGuard Super Master Components (5,000 Users, 10,000 FP Templates, 20,000 Transaction Records)

|
 |
 |
iGuard Components: Super Master Server Unit (10,000 Users, 20,000 FP Templates, 20,000 Transaction Records)

|
 |
 |
iGuard Super Master Components (20,000 Users, 40,000 FP Templates, 20,000 Transaction Records)

|
 |
 |
CONTACTLESS SMARTCARD With this feature, your workforce can gain access to the iGuard faster and smarter,
by using the Philips Mifare Contactless Smart Card.
Each user would have his / her own smart card,
which stores the user information including the name, company & branch code, and the fingerprint information.
Contactless smart cards contain an embedded antenna instead of contact pads attached to the chip for
reading and writing information contained in the chip's memory. Contactless cards do not have to be inserted into a card acceptor device.

|
 |
 |
TECHNOLOGY OVERVIEW Whether you are in an airport lounge or a hotel room, you can always check if your employees are
already in the office or not, and you can even control, modify or disable their access rights to
your office remotely via internet connection.

|
 |
 |
CAPACITIVE FINGERPRINT SENSOR The new fingerprint sensor features enhanced imaging capabilities, electrostatic discharge (ESD)
performance and improved ruggedness to provide superior levels of accuracy and reliability for fingerprint authentication.

|
 |
 |
BUILT-IN DATABASE SERVER The built-in Database Server allows obtaining the employee information and the access & attendance records easily,
thus cutting the processing time for jobs like payroll calculation from days to minutes.

|
 |
 |
MULTIPLE VERIFICATION METHODS With iGuard, users can be authenticated and verified through either Fingerprint,
Smartcard or Password.
Depending on the different time period, you can set up the iGuard that the users can just simply present
their smartcard to get authorized (such as during high-traffic period).
Or require high-security fingerprint verification (such as after office hours or during weekends and holidays).

|
 |
 |
ACCESS RIGHTS When you can easily and conveniently assign different access rights to your employees,
you can plan your security better and maximize the effectiveness of the human resources.
iGuard empowers you to manage the access rights of each individual employee easily anytime, anywhere
using any web-enabled computers or mobile devices.

|
 |
 |
STYLE & SIZE iGuard is a wall-mounted unit elegantly designed with extremely small footprint.
In fact, it is the smallest stand-alone biometrics device available in the market today.
105(W)mm x 38(D)mm x 150(H)mm
Simple clean lines allow iGuard to be mounted in sophisticated contemporary environments.

|
 |
 |
ADVANCED FEATURES Mulitple iGuard units can be setup as a Master/Slave network. Under this configuration,
one iGuard would be assigned as the Master, and all other units are configured as slaves.
When a user enroll's in any one of these iGuard units, his / her user information, including the fingerprint information,
would be replicated to all other iGuard units in the same master / slave network,
so the same user does not need to enroll multiple times
in order to have the access rights to all these units

|
 |
 |
REMOTE DOOR RELAY This controller further increases the security level by controlling the door strike
from inside of the premises. With this optional controller, the iGuard sends a special signal
to this controller to open the door, rather than directly open the door with the internal relay.
Because this optional controller is installed inside the premises, it is now impossible
for the intruders to get into the premises, even if they break the iGuard.

|
 |
 |
TYPICAL DOOR CONNECTION (12V DC) Power Plug. The power requirement is 12V DC, 600mA. Since most
of the door strikes require the same 12V DC power supply, iGuard may share the same power supply
with the door strike.
Door Strike (Optional)
Terminals #3-5 (3-4 Normal Open, 4-5 Normal Close).
These terminals are connected directly to the internal relay, rating at 12V / 5A.
If the door strike is within this current limit, it can be directly connected to these terminals.
If the system is used solely for Time Attendance System, these terminals can be left open.
Door Sensor (Optional)
Terminals #6-7. It provides iGuard the current status of the door (open / close).
If the door is left open for over 10 seconds, iGuard will generate beep sounds to alert the people.
Open Door Switch (Optional)
Terminals #8-9. An optional door switch can be connected to these terminals.
It is used to open the door remotely, such as opening the door from the inside of the business premises, or from the reception area.
External Alarm (Optional)
Terminals #10-11. This is used for optional external alarm.
If the case of the device is forced open during operation (such as a break-in),
an internal sensor will trigger this connection, and it will sound the external alarm.

|
 |
 |
ECONOMICAL INTELLIGENCE All the necessary hardware and software is built-in to the device, including the hardware
to connect the system to the corporate network.
All you need to do is to plug-in the popular RJ-45 network cable to the back of the device.
No other hardware and wiring is necessary.

|
 |
 |